MEC Full Port 1-1/4 in. FPT globe valve
MEC Full Port 1-1/4 in. FPT globe valve
Item # 2498873

All Marshall Excelsior globe and angle valves are designed to withstand extreme temperatures and can increase flow up to 70 % over a standard globe valve. The 35 seat angle on the 1-1/4 and larger globe valves make them ergonomically designed for bobtail, transport and bulk plant applications. This 35 seat angle also allows up to 70 % more ow. All 1-1/4 and larger globe and angle valves come with an upstream and downstream plugged port. The boss of these ports are large enough to drill and tap a 3/4 FNPT hole for a jumper line or standard by-pass valve. These valves are mainly used in piping systems to control liquid or vapor ow in bulk plants, bobtails, transports, pumps or compressors. Globe valves are designed to be installed in a straight section of piping and angle valves are designed to be installed when a 90 directional change is needed in the piping.

  • All stainless steel internal components with rotating seat disc design and V-cup Teflon packing stem seals
  • Double stem seal design ensures leak free operation
  • Rated for 400 WOG
  • Operating temperature 40 to +212°F
Units: Each
Qty:

Add to Favorites List Add to Customized Product OfferingPlease Wait Remove From Customized Product OfferingPlease Wait Add To Bin LabelsPlease Wait Added to Bin Labels. Click icon to print Bin Labels. Add To Custom CatalogPlease Wait Added To Custom Catalog. Click icon to print Custom Catalog. Email
MEC Full Port 3 in. FPT Angle Valve
MEC Full Port 3 in. FPT Angle Valve
Item # 2498878

All Marshall Excelsior globe and angle valves are designed to withstand extreme temperatures. To increase the longevity of the seal, all Marshall Excelsior globe and angle valves have a 360 rotating seal that stops rotating when it contacts the sealing surface while the valve continues to be tightened. These valves are mainly used in piping systems to control liquid or vapor ow in bulk plants, bobtails, transports, pumps or compressors. Installation Note: Before installing a globe or angle valve, the piping system and container must be free of dirt, debris, foreign matter and other particles, large or small, that could damage the sealing surface or seal of the valve. A minimal amount of pipe sealant should be used on the mating part. Excess pipe sealant can also cause damage to the seal surface or seal. Damage to the sealing surface or the seal will cause the valve to leak. To avoid damage to the valve or piping, due to pressure build-up from temperature changes, a hydrostatic relief valve should be installed where liquid can be trapped between 2 shutoff valves. A vent valve should be installed on the downstream side of the globe or angle valve if the angle valve is used as a shutoff valve at the end of a loading hose. This allows the operator to vent the trapped liquid before disconnect.

  • All stainless steel internal components with rotating seat disc design and V-cup Teflon packing stem seals
  • Double lead acme stem thread ensures quick and efficient operation
  • Rated for 400 WOG
  • Operating temperature 40 to +212°F
Units: Each
Qty:

Add to Favorites List Add to Customized Product OfferingPlease Wait Remove From Customized Product OfferingPlease Wait Add To Bin LabelsPlease Wait Added to Bin Labels. Click icon to print Bin Labels. Add To Custom CatalogPlease Wait Added To Custom Catalog. Click icon to print Custom Catalog. Email
MEC Full Port 2 in. FPT Globe Valve
MEC Full Port 2 in. FPT Globe Valve
Item # 2498874

All Marshall Excelsior globe and angle valves are designed to withstand extreme temperatures and can increase flow up to 70 % over a standard globe valve. The 35 seat angle on the 1-1/4 and larger globe valves make them ergonomically designed for bobtail, transport and bulk plant applications. This 35 seat angle also allows up to 70 % more flow. All 1-1/4 and larger globe and angle valves come with an upstream and downstream plugged port. The boss of these ports are large enough to drill and tap a 3/4 FNPT hole for a jumper line or standard by-pass valve. These valves are mainly used in piping systems to control liquid or vapor low in bulk plants, bobtails, transports, pumps or compressors. Globe valves are designed to be installed in a straight section of piping and angle valves are designed to be installed when a 90 directional change is needed in the piping.

  • All stainless steel internal components with rotating seat disc design and V-cup Teflon packing stem seals
  • Double lead acme stem thread ensures quick and efficient operation
  • Rated for 400 WOG
  • Operating temperature 40 to +212°F