Gas Ignition Controls
Non primary-aerated, insert orifice type pilot burner for main burner ignition. Used with Q309, Q340, Q390 thermocouples or Q313 thermopiles.
- Variety of tip directions to provide desired flame pattern.
- Interchangeable, color-coded orifices can be ordered to convert between natural and LP gas
- N/A
- N/A
Lennox Direct Replacement Integrated Furnace Control Single Stage Nitride Hot Surface Ignition for 80V Ignitors. Replaces Lennox 83M00, White-Rodgers 50A62-120, 50A62-121, 50A62-820, 50A66-843. Features diagnostic LED indicators to streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Goodman Direct Replacement Integrated Furnace Control. Replaces Goodman B1809913S, UTEC 1012-933D, TI 41F-5, White-Rodgers 50T35-730. Diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Direct OEM replacement for Trane single stage integrated furnace control for 80 volt hot surface igniters. Exact replacement makes replacement and service fast and simple. Replaces Trane CNT03076, CNT03798, CNT05164, CNT05165, D341213P01, D341396P01, D341396P03, D341396P04, D341396P05, White-Rodgers 50A65-474, -475, -476.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120V air cleaner output and 120V humidifier output up to 1 Amp max
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Direct OEM replacement for Trane single stage integrated furnace control for 120 volt hot surface igniters. Exact replacement makes replacement and service fast and simple. Replaces Trane CNT02789, CNT02891, CNT03799, D341122P01, D341235P01, D341235P03, White-Rodgers 50A55-474, -476, -571.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120V air cleaner output and 120V humidifier output up to 1 Amp max
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
This is a genuine GOODMAN replacement part. It is designed for use in HVAC applications. See installation guide for more details. Professional installation recommended.
- Built with quality in mind
- Replacement part
- Printed circuit board for furnaces
- Optimum performance
Carrier Direct Replacement Integrated Furnace Control 1 Stage Hot Surface Ignition for 120-Volt Ignitors. Replaces Carrier 325878-751, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034. Diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
- Single stage, hot surface ignition, 210 Vac, for PSC blower types
120-Volt Silicon Carbide Hot Surface Ignitor. 4-1/2 in. Leads, G Style Mounting Block, Insulation 200 degree C, Amp Terminal Connector. Includes Ceramic Wire Nuts. Replaces R/S 41-407
- Works with 15, 17 or 45 second HSI systems
- Includes ceramic wire nuts for cut and strip connections
- Extensive cross reference information on our website or download the WR Mobile App
- Operating Voltage 120 Vac, 60 Hz
- Easy install
This is a genuine Goodman replacement part. This ignitor can be used in HVAC gas ignition controls. It is compatible with Goodman packaged units.
- Furnace hot surface ignitor
- Fits Goodman furnaces
- Manufactured with quality in mind
- Compatible with Goodman furnaces
Universal Direct Spark Ignition Module. Replaces OEM and Competitive Controls Including Carrier, Trane, York, Lennox and S87 Series. Plug in program keys.
- Plug in program keys for quick selection of factory timings
- Microprocessor-based ignition control
- Works with single rod or dual rod remote sensor
- Provides ignition, proof of ignition and precise timings
- LED diagnostic indicator
- For use in natural and LP gas applications
Hot surface ignitor mini with 5.125 in. (+/-.5 in. ) leads including electrical connector. Now includes special mounting plate for older applications. Replaces R/S 41-602, amana 201657-03S, goodman 601, and goodman 0230K00001 conversion kit.
- Works with 15, 17 or 45 second HSI systems
- Includes ceramic wire nuts for cut and strip connections
- Extensive cross reference information on our website or download the WR mobile app
- Operating Voltage-120 Vac, 60 Hz
Universal Proven Pilot Spark Ignition Module. Replaces OEM and Competitive Controls Including Carrier, Trane, York, Lennox. Also Replaces Honeywell S8610U1003. Plug in program keys.
- Plug in program keys for quick selection of factory timings
- Microprocessor-based ignition control
- Works with single rod or dual rod remote sensor
- Provides ignition, proof of ignition and precise timings
- LED diagnostic indicator
- For use in natural and LP gas applications
Goodman OEM Control Board
- Integrated Control, 2 Stage.
Goodman Direct Replacement Integrated Furnace Control Hot Surface Ignition for Multi-Speed Applications. Replaces Goodman 0130F00006(S), PCB00109, PCBBF109(S), PCBBF122(S), PCBBF132(S), PBCBF159(S), White-Rodgers 50M56-289 and 290. Features diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Goodman Ignition Control Board
- DSI Integrated
- Designed for 100% gas shutoff in case of ignition failure Reverse polarity protection Compatible with 24 VAC standard thermostat.
The Robertshaw 780 Series Pilot Controls feature flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. When the thermostat calls for heat, the 780 series control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.
- Reduces truck stock inventory, saving space and money
- Easy-to-install with complete in-depth installation instructions
- Pilot and main valves draw 1 Amp at 0.5 power factor
- Combined load at 1.5 Amps at 0.4 power factor
- 95% relative humidity noncondensing at 104 degree F
Lennox / Allied Air Direct Replacement Integrated Furnace Control Kit. Use for Single Stage 120V Hot Surface Ignition and 2 or 3-Speed PSC Blower Motors. Features Diagnostic LED and Push-Button Fault Recall. Includes Dipswitches for Easy Blower Delay Configuration. Replaces 56W19, 74W03, 81W03, 94W83 and More.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
- Features diagnostic LED and push-button fault recall, includes dipswitches for easy blower delay configuration
This is Photoconductive Flame Sensor For Sequencing Oil Burner Systems. Shuts Down Protectorelay (#506610) When Flame Goes Out. 60" Leads Includes Mounting Bracket.
Universal Integrated Furnace Control Two-Stage Hot Surface Ignition for 3-Speed (ECM Blower Motor Systems). Includes 21D64-2 Universal Silicon Nitride Ignitor Upgrade Kit. Replaces White-Rodgers 50V51-xxx and 50V61-xxx 2-Stage HSI Systems with 80-Volt or 120-Volt Ignitors
- Reduces inventory by providing maximum control replacement coverage
- Includes a universal 120V nitride ignitor to allow replacement of 80V and 120V controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120V air cleaner output and 120V humidifier output up to 1 Amp max
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
- Bracket for Magic-Pak Pilot Assembly
- Use with HWC Model Units
- Use with R05701B004 pilot assembly
- Magic-Pak Pilot Tube Assembly
- Use with 36HWC, 48HWC, and 60HWC Model Units.
- Magic-Pak Lighter Tube
- Use with 60HWC and 66HWC Model Units.