Searched for "oatey"
- Heavy Duty Clear cement for use on all schedules and classes PVC pipe and fitting up to 12” diameter with interference fit, up to 18” for non-pressure
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Thick formula fills gaps in large diameter pipe and loose fitting joints
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Medium-bodied milky-clear cement for use on all schedules and classes of ABS, PVC and CPVC* pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets performance requirements of ASTM D-2564, D-2235, F-493
- Always check local codes for acceptability of this product
Log in to see your price and availability |
- Regular-Bodied Clear cement for use on all schedules and classes of PVC pipe and fittings up to 4” for Sch 40 and up to 2” for Sch 80
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Regular-Bodied Clear cement for use on all schedules and classes of PVC pipe and fittings up to 4” for Sch 40 and up to 2” for Sch 80
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Medium-bodied blue cement for use on all schedules and classes of PVC pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements Very fast-setting “Hot” cement formulated for wet conditions and/or quick pressurization and fast installation
- Recommended for pool, irrigation, potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- No primer needed on non-pressure DWV, up through 6” diameter where local codes permit
- Meets ASTM D-2564
Log in to see your price and availability |
- Purple-tinted aggressive primer for use on PVC and CPVC pipe and fittings
- Low Voc
- Primer meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Removes surface dirt, grease and grime as well as softens the pipe surface to allow a fast, secure solvent weld
- For use in areas where plumbing code calls for verification that a primer has been used
- NSF Listed
- Meets ASTM F-656
- Purple-tinted aggressive primer for use on PVC and CPVC pipe and fittings
- Low Voc
- Primer meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Removes surface dirt, grease and grime as well as softens the pipe surface to allow a fast, secure solvent weld
- For use in areas where plumbing code calls for verification that a primer has been used
- NSF Listed
- Meets ASTM F-656
- For copper tube size (CTS) CPVC hot and cold potable water pipe and fittings up to 2" diameter interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- For cold water systems and hot water systems up to 200°F / 93°C
- May be used without primer where local coders permit
- Recommended application temperature 0°F to 110°F / -17°C to 43°C
- Meets ASTM F493
- FlowGuard Gold is a registered trademark of The Lubrizol Corporation
Log in to see your price and availability |
- Regular-Bodied Clear cement for use on all schedules and classes of PVC pipe and fittings up to 4” for Sch 40 and up to 2” for Sch 80
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Purple-tinted aggressive primer for use on PVC and CPVC pipe and fittings
- Low Voc
- Primer meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Removes surface dirt, grease and grime as well as softens the pipe surface to allow a fast, secure solvent weld
- For use in areas where plumbing code calls for verification that a primer has been used
- NSF Listed
- Meets ASTM F-656
- Medium-bodied blue cement for use on all schedules and classes of PVC pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements Very fast-setting “Hot” cement formulated for wet conditions and/or quick pressurization and fast installation
- Recommended for pool, irrigation, potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- No primer needed on non-pressure DWV, up through 6” diameter where local codes permit
- Meets ASTM D-2564
Log in to see your price and availability |
- Heavy Duty Clear cement for use on all schedules and classes PVC pipe and fitting up to 12” diameter with interference fit, up to 18” for non-pressure
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Thick formula fills gaps in large diameter pipe and loose fitting joints
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Medium-bodied blue cement for use on all schedules and classes of PVC pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements Very fast-setting “Hot” cement formulated for wet conditions and/or quick pressurization and fast installation
- Recommended for pool, irrigation, potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- No primer needed on non-pressure DWV, up through 6” diameter where local codes permit
- Meets ASTM D-2564
Log in to see your price and availability |
- Clear Cleaner for ABS, PVC and CPVC pipe and fittings
- Low Voc
- Solvent Cement meets SCAQMD 1171/316A or BAAQMD Method 40 and various environmental requirements
- All schedules and all diameters
- Flows freely and evaporates quickly
- Fast acting cleaner removes surface dirt, grease and grime
Log in to see your price and availability |
- For copper tube size (CTS) CPVC hot and cold potable water pipe and fittings up to 2" diameter interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- For cold water systems and hot water systems up to 200°F / 93°C
- May be used without primer where local coders permit
- Recommended application temperature 0°F to 110°F / -17°C to 43°C
- Meets ASTM F493
- FlowGuard Gold is a registered trademark of The Lubrizol Corporation
Log in to see your price and availability |
Cleans and Fluxes
- Effective On All Metals Except Aluminum and Stainless Steel
Log in to see your price and availability |
- Medium-Bodied Black cement for use on all schedules and classes of ABS pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- For all non-pressure applications
- Recommended application temperature 40°F to 110°F/ 4°C to 43°C
- Meets ASTM D-2235
Log in to see your price and availability |
- Clear aggressive primer for use on PVC and CPVC pipe and fittings
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Removes surface dirt, grease and grime as well as softens the pipe surface to allow a fast, secure solvent weld
- NSF listed
- Meets ASTM F656
Log in to see your price and availability |
- Clear Cleaner for ABS, PVC and CPVC pipe and fittings
- Low Voc
- Solvent Cement meets SCAQMD 1171/316A or BAAQMD Method 40 and various environmental requirements
- All schedules and all diameters
- Flows freely and evaporates quickly
- Fast acting cleaner removes surface dirt, grease and grime
Log in to see your price and availability |
- Heavy Duty Clear cement for use on all schedules and classes PVC pipe and fitting up to 12” diameter with interference fit, up to 18” for non-pressure
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Thick formula fills gaps in large diameter pipe and loose fitting joints
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets ASTM D-2564
Log in to see your price and availability |
- Clear Cleaner for ABS, PVC and CPVC pipe and fittings
- Low Voc
- Solvent Cement meets SCAQMD 1171/316A or BAAQMD Method 40 and various environmental requirements
- All schedules and all diameters
- Flows freely and evaporates quickly
- Fast acting cleaner removes surface dirt, grease and grime
Log in to see your price and availability |
- Medium-bodied milky-clear cement for use on all schedules and classes of ABS, PVC and CPVC* pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- Recommended for potable water, pressure pipe, conduit and DWV
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Meets performance requirements of ASTM D-2564, D-2235, F-493
- Always check local codes for acceptability of this product
Log in to see your price and availability |
- Oatey® Rain-R-Shine® Medium Blue PVC Cement is formulated for wet conditions or situations involving fast installation or pressurization of PVC pipe and fittings up to 6" diameter with interference fit.
Log in to see your price and availability |
- Medium-Bodied Orange cement for use on all schedules and classes of CPVC pipe and fittings up to 6” diameter with interference fit
- Low Voc
- Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements
- For Residential and Commercial hot and cold water systems up to 200°F / 93°C
- Recommended application temperature 40°F to 110°F / 4°C to 43°C
- Approved for Corzan® CPVC Piping Systems
- Meets ASTM F-493 and ASTM D-2846
- Corzan® is a registered trademark of The Lubrizol Corporation
Log in to see your price and availability |